Representative photograph, actual product appearance may vary.

Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell office regarding your product of choice.
 
GXE51A1B
Explosion-Proof Limit Switches Series GXS: Side Rotary; 1NC 1NO SPDT Snap Action; 5 m Cable
Features
  • II 2 G EExd IIC T6
  • KEMA 00 ATEX 2103 X
  • Conforms to EN50014, EN50018, CE marked
  • EN50047 mounting compatible
  • Rugged zinc die-cast housing
  • Pre-wired - 5 metres of cable
  • Bottom exit cable ONLY
  • Double insulated switch element
  • Snap action basic switch
Typical Applications
  • Hazardous areas Category 2 (Zone 1) or Category 3 (Zone 2)
  • Petrochemical
  • Material handling
  • Valve
Description
The GXS series explosion proof limit switches are designed specifically for use in hazardous applications. The GXS enclosure is fully potted and has sealing protection of IP66/67 as per IEC/EN 60529. The entire series GXS complies with the European Directive on Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres (94/9/EC) commonly referred to as the ATEX Directive.


GXE51A1B
Explosion-Proof Limit Switches Series GXS: Side Rotary; 1NC 1NO SPDT Snap Action; 5 m Cable
Product Specifications
  Availability   Europe; Asia-Pacific
  Product Type   Explosion-Proof Limit Switches
  Actuator   Side Rotary
  Lever Style   Roller - Standard
  Circuitry   1NC 1NO SPDT Snap Action
  Ampere Rating   5 A (Thermal)
  Supply Voltage   240 Vac
  Housing Material   Zinc Die-Cast
  Termination Type   5 m Cable
  Series Name   GXS Series
  Sealing   IP67
  Approvals   CE Certified, KEMA 00 ATEX 2103 X
  Mechanical Life   up to 2 million
  Operating Temperature Range   -25 °C to 75 °C (35 °F to 168 °F)
  Comment   Bottom Exit Cable; Explosion Proof Construction EEx d IIC T6
  Agency Approvals and Standards   EN50014, EN50018, IEC947-5-1, EN60947-5-1
  UNSPSC Code   302119
  UNSPSC Commodity   302119 Switches and controls and relays
  Sealed   Explosion-proof


GXE51A1B
Explosion-Proof Limit Switches Series GXS: Side Rotary; 1NC 1NO SPDT Snap Action; 5 m Cable

PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

 

MISUSE OF DOCUMENTATION
  • The information presented in this product sheet (or catalog) is for reference only. DO NOT USE this document as product installation information.
  • Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.

© Copyright Honeywell Inc.1998-2004 All rights reserved.